h2 isotope analysis peak shift
From:
Chancy Fessler <[log in to unmask]>
Reply To:
Stable Isotope Geochemistry <[log in to unmask]>
Date:
Mon, 30 Jul 2007 17:46:09 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (6 lines)
we're doing GC-pyrolysis on a MAT-253 for H2 isotope analysis. However, our 
chromatography looks a little odd in a sense that the mass 3 trace tails behind 
the mass 2 trace of the chromatography peaks and the mass 2 ad 3 apeces 
do not always match: an inverse time-shift so-to-speak. Any word of wisdom 
on how to handle this problem?