Skip Navigational Links
LISTSERV email list manager
LISTSERV - LIST.UVM.EDU
LISTSERV Menu
Log In
Log In
LISTSERV 17.5 Help - UVMFLOWNET Archives
LISTSERV Archives
LISTSERV Archives
Search Archives
Search Archives
Register
Register
Log In
Log In

UVMFLOWNET Archives

March 2018

UVMFLOWNET@LIST.UVM.EDU

Menu
LISTSERV Archives LISTSERV Archives
UVMFLOWNET Home UVMFLOWNET Home
UVMFLOWNET March 2018

Log In Log In
Register Register

Subscribe or Unsubscribe Subscribe or Unsubscribe

Search Archives Search Archives
Options: Use Monospaced Font
Show HTML Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
Volume Flow Artifacts
From:
Steve Knight <[log in to unmask]>
Reply To:
UVM Flownet <[log in to unmask]>
Date:
Wed, 7 Mar 2018 10:06:55 -0500
Content-Type:
multipart/alternative
Parts/Attachments:
text/plain (820 bytes) , text/html (999 bytes)
I reviewed a case of an AVF exam that had very low Volume Flow Velocities
reported (less than 0.06 L/min). The waveforms  were obtained approx 5 cm
distal to the arterial anastomosis in a straight uniform vein section one
month post-op and looked normal in shape. Velocities were not impressively
low. Diameter was about 2.2cm. 4 cardiac cycles were included in the
calculation. The autotrace of peak velocity and mean velocity tracked the
spectral profile without noticeable deviation. The series of beats measured
did include a PVC with a low EDV. Also, the degree of fistula maturity may
be a factor. I would like to hear others who do a lot of Vol Flow
measurements of early dialysis fistulas weigh in here.
Thanks,

Steve K