The Philips people need to be contacted because the protocol has not
changed. It is still 140 cm/s EDV for 80-99%.
Jean Primozich
----- Original Message -----
From: "Hodge, Megan D." <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, November 21, 2002 7:21 AM
Subject: Re: ICA criteria in the new Phillilps protocol guide
> great observation.. I wonder if any one else saw that. because I sure
> didn't!!!!!.. We have always used 140 cm/sec with great specificity and
> sensitivity.
>
>
> > -----Original Message-----
> > From: Stanley, Jeff [SMTP:[log in to unmask]]
> > Sent: Thursday, November 21, 2002 8:53 AM
> > To: [log in to unmask]
> > Subject: ICA criteria in the new Phillilps protocol guide
> >
> > To Jean Primozich or anyone else who may know;
> > I noticed that the EDV criteria for 80-99% stenosis is listed as 125
> > cm/sec, not 140 cm/sec, in the new protocol guide. True? Typo?
> >
> > Jeff Stanley BS,RVT
> > The Heart Group
> > Diagnostics-Vascular Lab
> > 4230 Harding Road, Suite 330
> > Nashville, Tennessee 37205
> > (615) 565-6580
> > [log in to unmask]
> >
>