Print

Print


Message
YOU ARE CORRECT, NO-ONE INCLUDING MYSELF HAS MUCH IF ANY EXPERIENCE WITH PRE AND POST STENT GRAFT MEASUREMENTS WITH IVUS. WE WERE JUST KIND OF THROWN INTO THE FIRE WITH IT WHEN WE DID THE FIRST FEW STENT GRAFTS, IVUS SEEMED TO NOT BE AS HELPFUL AS THEY THOUGHT PLUS, WE AS TECHS WERE NEVER GIVEN ANY INSTRUCTION OF HOW TO PROPERLY USE THE MACHINE. IT WAS A BAD COMBINATION AND WE STOPPED GETTING CALLS FOR STENT GRAFT IVUS USE. WE MOSTLY USE IVUS FOR CARDIAC ABLATION CASES NOW. WE STILL TO THIS DAY HAVE NEVER HAD ANY TRAINING ON THE MACHINE THOUGH JUST EXPERIENCE AND AN INSTRUCTION MANUAL.
 
SORRY IF THE CAPITAL LETTERS BOTHERED YOU.
 
GREG
-----Original Message-----
From: Johnson, Bonnie [mailto:[log in to unmask]]
Sent: Thursday, October 20, 2005 11:46 AM
To: [log in to unmask]
Subject: Re: IVUS

I have limited experience with the use of IVUS in EVAR.  Our experience has demonstrated that inaccurate neck measurements are often obtained as a result of the curvature of the catheter and this causes oblique sections through the neck. It is available for use but does not seem to be used with regularity anymore here.   bj

 

Bonnie L. Johnson RDMS, RVT, FSVU

Stanford University Medical Center

Director, Vascular Laboratory Services

Division of Vascular Surgery

 

 

-----Original Message-----
From:
UVM Flownet [mailto:[log in to unmask]] On Behalf Of Needham, Terry
Sent: Thursday, October 20, 2005 6:07 AM
To: [log in to unmask]
Subject: IVUS

 

Does anyone have info regarding the use of IVUS for the pre/post op assessment of aortic stent grafts?  Thanks, Terry N.

 

 

Terry Needham

Heart & Vascular

Erlanger Health System

423-778-5839

PLEASE  NOTE MY NEW EMAIL ADDRESS

[log in to unmask]

 


The information or documents contained in this electronic mail message is intended to be privileged and confidential information only for the use of [log in to unmask] or entity named herein or above. If you are not [log in to unmask] or the intended recipient, you are hereby notified that any dissemination, distribution or copy of this message or document is strictly prohibited. If you have received this electronic mail transmission in error, notify [log in to unmask] by e-mail and delete all copies from your system. Erlanger Health System is not responsible for errors in this electronic mail message. Any personal comments made do not necessarily reflect the views of Erlanger Health System.

To unsubscribe or search other topics on UVM Flownet link to: http://list.uvm.edu/archives/uvmflownet.html To unsubscribe or search other topics on UVM Flownet link to: http://list.uvm.edu/archives/uvmflownet.html