Hi Fred,
 
 
I will send you off-list a couple of my papers on this subject.  Pier de Groot's Handbook on Stable Isotope Analytical Techniques is also a great resource in this regard.
 
There is also a book in the pipeline on CSIA by GC-IRMS to watch out for. Authors are Jochmann & Schmidt and estimated date of release is 31 Oct this year.
 
 
Best,
 
Wolfram
 

****************************************
"Facts do not cease to exist because they are ignored."
Aldous Huxley, "Proper Studies", 1927

****************************************
Dr W Meier-Augenstein, CChem, FRSC
Principal Scientist - Stable Isotopes
The James Hutton Institute

http://www.hutton.ac.uk 

Head of Mylnefield Isotope Signatures
 
http://www.isotopesignatures.co.uk

Director of FIRMS plc
http://www.forensic-isotopes.org/

Stable Isotope Forensics book:
http://eu.wiley.com/WileyCDA/WileyTitle/productCd-0470517050.html

E-mail: [log in to unmask]
Tel.: +44 (0)1382 568781
Fax: +44 (0)1382 568544

Attention
This message contains privileged and confidential information intended for the addressee(s) only. If this message was sent to you in error, you must not disseminate, copy or take any action in reliance on it and we request that you notify the sender immediately by return email.

Opinions expressed in this message and any attachments are not necessarily those held by JHI or any person connected with the organisation, save those by whom the opinions were expressed.

 

 


From: Stable Isotope Geochemistry [mailto:[log in to unmask]] On Behalf Of Fred Martin Kaaby
Sent: 04 May 2011 14:27
To: [log in to unmask]
Subject: [ISOGEOCHEM] GC-IRMS, peak shape and how it affect stable isotope ratios for carbon and hydrogen

Dear IsoGeochem

 

I have very difficult to find literature that concerns the subject of the quality of the chromatography and how it affects the stable isotope ratios in GC-IRMS.

I’m thinking especially about peak shape (tailing/fronting, overload, poor oxidation/reduction of oven, leakages, bad column etc), and not so much about poor separation.

 

Has anyone on this list done studies into this subject, that could tell me a little about it, or maybe show some data on it? How does peak shape, background and signal strength correlate and affect the isotope ratios?

 

Thank you very much!

 

Best regards,

Fred Martin Kaaby


________________________________________________________

This email is from The James Hutton Institute (JHI), however the views
expressed by the sender are not necessarily the views of JHI and its
subsidiaries. This email and any attachments are confidential and are
intended solely for the use of the recipient(s) to whom they are addressed.
If you are not the intended recipient, you should not read, copy,
disclose or rely on any information contained in this email, and we would
ask you to contact the sender immediately and delete the email from your
system. Although JHI has taken reasonable precautions to ensure no
viruses are present in this email, neither the Institute nor the sender
accepts any responsibility for any viruses, and it is your responsibility to
scan the email and any attachments.

The James Hutton Institute is a Scottish charitable company limited by
guarantee.
Registered in Edinburgh No. SC374831
Registered Office: The James Hutton Institute, Invergowrie Dundee DD2 5DA.
Charity No. SC041796